Project Description
Product Details
Saunova 2.0 is a practical control for small heaters up to 9 kilowatts. Perfect combined with Ni2 heaters, on which you will no longer need to have separate power controller.
Saunova 2.0 user interface can be placed inside or outside the sauna room! The system is with a smart controlling that alternately shuts down a heating element when a set temperature is reached. This process reduces temperature fluctuations that keeps heating elements to work at a balanced pace. Even more precise temperature measuring with additional bench sensor.
Technical Data
Product Codes
SAU-UI-V2 (Saunova 2.0 Interface)
SAU-PC-V2 (Saunova Power Controller)
Description | Power Rating | Remarks |
---|---|---|
Control
|
||
Rated Power 3 Phases
|
9kW AC1 (3x3kW)
|
|
Rated Voltage 3 Phases
|
400V 3N~
|
|
Rated Power Single Phases
|
9kW AC1
|
|
Rated Voltage Single Phases
|
230V 1N~
|
|
Frequency
|
50/60Hz
|
|
Switching capacity per phase
|
16A
|
|
Sauna temperature range
|
10-110°C
|
|
Maximum session time(preset)
|
1, 2, 4, 6, 8, 12, 18, 24h
|
Restrictions apply according to IEC/EN 60335-2-53
|
Dimensions Saunova 2.0
|
||
User Interface
|
(W) 104 x (H) 147 x (D) 37
|
|
Power Controller
|
(W) 265 x (H) 245 x (D) 75
|
|
Weight INNOVA S types
|
||
User Interface
|
350g
|
|
Power Controller
|
1150g
|
|
Rated Power 3 Phases
|
5kW AC1
|
|
Rated Power Single Phases
|
3kW AC1
|
|
Rated Voltage
|
230V 1N~
|
|
Switching capacity
|
16A
|
|
Maximum sauna temperature for steamer operation
|
80°C or *55°C
*Depending on the type of Sensor 2. |
|
Automatic water filling
|
Optional
|
|
Cabin Light
|
Min 20W, max 100W.
|
|
Rating
|
230V 1N~, 100W AC1
|
|
Fan
|
Fan without starting capacitor. |
|
Rating
|
230V 1N~,0.5A
|
|
Power Extension Unit
|
Additional Power expansion to a maximum of 18kW | |
Rated Power 3 Phases
|
9kW AC1(3x3kW)
|
|
Rated Voltages 3 Phases
|
400V 3N~
|
|
Frequency
|
50/60Hz
|
|
Switching capacity per phase
|
16A
|
|
Sensor
|
||
Bench Temperature Sensor
|
||
Bench Sensors
|
||
Bench Temperature Sensor
|
Optional
|
|
Bench Combined Temperature –
Humidity Sensor |
Optionalv
|