Project Description
- Animated buttons for easy use
- Weekly timer for complete weeks’ sauna sessions
- Optional light dimmer, fan and Combi functions
- Remote controlling with potential free contact
- Auto-drying of sauna (with optional fan-feature)
- Easy mode for simplified use
- Key lock to prevent unauthorized person from changing settings
- Temperature display in Celcius or Fahrenheit
- Built-in power consumption counter
- Blackout memory for preserving your settings during electrical failure
- Additional bench temperature sensor can be installed for more precise temperature measuring
- Additional humidity & temperature sensor can be installed for measuring relative humidity
Product Codes
INT-SET (Innova Touch Interface + Power Controller)
INT-S (Innova Touch Interface)
INP-C (Power Controller)
———–
INT-SET-C (Interface + Power Controller with Combi Feature)
INP-C-C (Power Controller with Combi Feature)
Product Details
Controlling your sauna with Innova Touch is made easy and simple as it is equipped with clear LCD touch screen and state-of-art technology.
Technical Data
Description | Power Rating | Remarks |
---|---|---|
Control
|
||
Rated Power 3 Phases
|
15kW AC1 (3x5kW)
|
|
Rated Voltage 3 Phases
|
400V 3N~
|
|
Rated Power Single Phases
|
9kW AC1
|
|
Rated Voltage Single Phases
|
230V 1N~
|
|
Frequency
|
50/60Hz
|
|
Switching capacity per phase
|
21A
|
|
Sauna temperature range
|
40-110°C
|
|
Maximum session time(preset)
|
4,6,12,18,24h
|
Restrictions apply according to IEC/EN 60335-2-53
|
Dimensions INNOVA S types
|
||
User Interface
|
(W) 180 x (H) 105 x (D) 31
|
|
Power Controller
|
(W) 265 x (H) 245 x (D) 75
|
|
Dimensions INNOVA B types
|
(W) 265 x (H) 245 x (D) 75
|
|
Weight INNOVA S types
|
||
User Interface
|
150g (Touch)
|
|
Power Controller
|
1500g
|
|
Weight INNOVA B types
|
1630g(Touch)
|
|
Steamer
|
Optional
|
|
Rated Power 3 Phases
|
5kW AC1
|
|
Rated Power Single Phases
|
3kW AC1
|
|
Rated Voltage
|
230V 1N~
|
|
Switching capacity
|
21A(3 Phases), 13A (1 Phase)
|
|
Maximum sauna temperature for steamer operation
|
80°C or *55°C *Depending on the type of Sensor 2.
|
|
Automatic water filling
|
Optional
|
|
Automatic drain valve
|
Optional
|
|
Cabin Light
|
Dimmer optional
|
|
Rating
|
230V 1N~,100W AC1
|
|
Fan
|
Optional (with speed control)
|
|
Rating
|
230V 1N~,0.5A
|
|
Power Extension Unit
|
Additional Power expansion to maximum of 30kW
|
|
Rated Power 3 Phases
|
15kW AC1(3x5kW)
|
|
Rated Voltages 3 Phases
|
400V 3N~
|
|
Frequency
|
50/60Hz
|
|
Switching capacity per phase
|
21A
|
|
Sensor
|
Dimmer optional
|
|
Bench Temperature Sensor
|
||
Bench Sensors
|
||
Bench Temperature Sensor
|
Optional
|
|
Bench Combined Temperature – Humidity Sensor
|
Optional
|